Kirkhollow Analytical Laboratories Ltd


Sample Reception and Handling
Procedure KAL-SP-06 · Revision 4 · Effective 1 March 2026


# Scope


This procedure covers the receipt, identification, storage and disposal of samples submitted to the laboratory for
chemical analysis. It applies to everything received at the Braithe Road reception, including samples delivered
by courier and samples brought in by clients. It does not cover samples taken by our own field staff, which are
dealt with in KAL-SP-11.


# Reception


Samples are received at reception between 08:00 and 17:30 on weekdays and between 09:00 and 12:00 on
Saturdays. Outside those hours clients who hold a key may use the refrigerated drop box at the rear entrance.


# Chain of custody


Every delivery arrives with a completed submission form. Reception staff check that the form is signed, that the
number of containers matches the number listed on it, and that each container carries a legible client reference.
The form is signed and timed on receipt and the top copy is returned to the person making the delivery.


# Condition on arrival


Reception staff record the condition of each container on the submission form before it leaves the reception
bench. Anything recorded there that falls outside the limits below goes to the duty chemist before the sample is
booked in.


# Temperature


Chilled samples. Where the submission form specifies chilled transport, the temperature of the transport box is
measured and written on the form. A box above 8 degrees is accepted, marked, and referred to the duty chemist,
who decides whether the analysis can still be reported. A box above 15 degrees is not accepted for
microbiological work at all.


# Container integrity


Containers that are cracked, leaking, or filled above the shoulder are photographed on the reception bench and
set aside, and the client is telephoned the same day. A leaking container is not opened at reception.


# Storage


# Refrigerated storage


Samples for chemical analysis are held at 4 degrees in the reception cold room and are racked by the day of
receipt, not by client. Racks are cleared every Friday afternoon.


# Frozen storage


Samples that require frozen storage are held at minus 20 degrees in the chest freezer in room 4. Nothing goes
into the freezer without a completed freezer label, and nothing is stacked above the load line marked inside the
cabinet.


# Retention and disposal


Analysed samples are kept for twenty-eight days after the report is issued and are then disposed of by the route
set out in KAL-SP-19. Samples held longer at a client's request are labelled with the agreed retention date and
reviewed monthly by the laboratory manager.




## Records


Submission forms, condition records and the reception log are kept for six years. The reception log is a bound
book: entries are not erased, and a correction is made by a single line through the original, initialled and dated.


# Responsibilities


The laboratory manager owns this procedure. Reception staff carry it out; the duty chemist decides anything it
refers to them; and the quality manager audits it twice a year against the reception log and the submission forms.


# Reception staff


Reception staff check every delivery against its form, record the condition of each container, book the
submission in, and put the samples into the right storage within thirty minutes of accepting them. They do not
decide whether a sample outside the limits above can be analysed, and they are not asked to.


# The duty chemist


The duty chemist is named on the board in reception for each working day. They decide whether a sample that
arrived outside the limits can be reported and on what terms, record the decision on the submission form and
initial it, and tell the client where the decision changes what the report will say.


# Identification and booking in


# The laboratory number


Numbers run in one sequence for the whole laboratory and are never reused, including where a submission is
rejected after being numbered. The number and the year are written on the container as well as on the form,
because a container that has lost its label is a container nobody can report.


# Splitting a submission


Where determinations on one sample must be done in different sections, the sample is split at reception and each
part carries the laboratory number with a suffix. The split is recorded on the form with the volume in each part.


# Sub-samples for microbiology


A sub-sample for microbiological work is taken first, before any other part is poured, and is taken in the
reception cabinet rather than on the open bench. Where the volume received is too small to allow that, the
microbiological determinations are refused rather than taken second.


# Storage capacity


The reception cold room holds forty racks and the freezer sixty labelled boxes. Where either is full, reception
tells the duty chemist before accepting anything further into it. A sample put into the wrong storage is worse
than a sample refused: the refusal is visible and the wrong storage is not.


# Weekly clearance


Racks are cleared every Friday afternoon against the booking-in record. A sample still in the cold room after its
retention date is disposed of by the route in KAL-SP-19 and the disposal is logged. A sample in the cold room
with no record at all is not disposed of: it goes to the duty chemist, because an unrecorded sample is a failure
somewhere earlier in this procedure.


# Transport boxes and returns


Transport boxes belonging to the laboratory are emptied, wiped and returned on the next round to the client they
came from. Boxes belonging to a client are emptied and returned unwashed unless the client asks otherwise. Ice
packs are refrozen and reused; a leaking ice pack is thrown away rather than refrozen.




## Out-of-hours deliveries


The refrigerated drop box is checked at 08:00 every weekday and at 09:00 on Saturdays. Anything in it is
booked in as arriving at the time of the check and not at the time it was left, and clients are told that is the
practice when a key is issued. The box is not checked on Sundays or public holidays, and clients are asked not to
use it on the day before one.


# Deviations


A deviation from this procedure is recorded on the submission form and in the reception log, with the reason
and the name of whoever authorised it. Deviations are reviewed monthly by the laboratory manager and again at
each audit. A deviation that has happened three times is a sign that the procedure is wrong rather than the staff,
and is raised as such.


# Complaints


A client complaint about the condition or the handling of a sample goes to the laboratory manager on the day it
is received and is acknowledged within one working day. The reception log, the submission form and the
condition record are copied into the complaint file before anything else is done, because they are the only
evidence of what arrived.


# Training


Nobody works reception unsupervised until they have been through this procedure with the laboratory manager,
worked two full days alongside someone who has, and had their first ten submissions checked. Training is
recorded on the individual's file, and the record says who signed each stage off.


# Revision history


Revision 4 adds the drop box and the fifteen-degree limit for microbiological work, and moves the retention
period from twenty-one days to twenty-eight. Revision 3 followed the 2024 audit and rewrote the condition
records. Revisions 1 and 2 are held in the controlled document file and are not in circulation.