TC94 evidence -- RAGFlow Cloud, Grounded Generation (C34), chat assistant on defaults dataset: R6-stable-SS-v1 (b09c2f28cbb011f1916c37b82c69031d), slice SS-v1 digest 64131a7b2f68b281 chat assistant config (POST /api/v1/chats with only name + dataset_ids; everything else default): { "name": "R6-stable-SS-v1-chat", "id": "4185996ecd2f11f1a062a9d444378041", "llm_id": "gpt-5.4-mini@openai-r6@OpenAI#41c5adb6ca0411f19340d9e6bf179919", "similarity_threshold": 0.1, "vector_similarity_weight": 0.3, "top_n": 6, "top_k": 1024, "rerank_id": "", "prompt_type": "simple", "language": "English", "do_refer": "1" } prompt_config: { "empty_response": "Sorry! No relevant content was found in the knowledge base!", "parameters": [ { "key": "knowledge", "optional": false } ], "prologue": "Hi! I'm your assistant. What can I do for you?", "quote": true, "refine_multiturn": true, "system": "You are an intelligent assistant. Please summarize the content of the dataset to answer the question. Please list the data in the dataset and answer in detail. When all dataset content is irrelevant to the question, your answer must include the sentence \"The answer you are looking for is not found in the dataset!\" Answers need to consider chat history.\n Here is the knowledge base:\n {knowledge}\n The above is the knowledge base.", "tts": false } ######## RUN 1: POST /api/v1/chat/completions question='How quickly does Fenwake acknowledge a Priority 1 fault reported outside business hours?' stream=false | HTTP 200 code=0 latency=2.93s ANSWER: Fenwake acknowledges a Priority 1 fault reported outside business hours within 90 minutes of the ticket being raised, with a named duty engineer confirming ownership by telephone and, if requested, in writing on the ticket [ID:0]. === [ID:0] similarity=0.4826 (vector 0.7948, term 0.3488) | A01_field_service_policy_and_charges_uk.pdf 5.2Access Where a site requires a permit, an induction or a vessel movement, the attendance clock is suspended until access is confirmed in writing. The suspension is recorded on the ticket with the reason. 6.Out-of-hours cover Outside business hours the service desk is not staffed. A duty engineer rota covers every hour of the year, and the out-of-hours number in section 8 pages the engineer on call. 6.1Acknowledgementout ofhours A Priority 1 fault reported outside business hours is acknowledged by a named duty engineer within 90 minutes of the ticket being raised. The engineer confirms ownership by telephone and, where the customer asks for it, in writing on the ticket. The target applies on every cover level; the cover level determines what happens after acknowledgement, not how quickly the call is answered. 6.2Whatfollows acknowledgement Having acknowledged, the duty engineer attempts a remote diagnosis using the telemetry record. Where the fault cannot be cleared remotely, attendance is arranged under section 5 from the start of the following working day, except on Critical cover, where the duty engineer may authorise attendance immediately 6.3Priority 2 and Priority 3 out of hours Priority 2 and Priority 3 tickets raised outside business hours are queued and acknowledged when the service desk opens. The business-hours targets in section 4 then apply from opening. 7.Escalation A customer may escalate at any time, and the service desk escalates on its own initiative when a target is missed. Each step below is a named person, not a queue. · Step 1 - Duty engineer. Owns the ticket and the diagnosis · Step 2 - Service desk lead. Owns the schedule, the parts and the customer communication. · Step 3 - Head of service operations. Owns the commercial consequences and any goodwill offered. · Step 4 - Operations director. Owns the relationship. A step is skipped only where the person is unavailable, and the skip is recorded. Escalation does not restart the acknowledgement clock, which is measured once per ticket. 7.1 Missed targets Where an acknowledgement target is missed, the service desk lead writes to the customer within one working day setting out what happened and what has changed. A missed target is reported in the monthly service review whether or not the customer raises it. 8. Contacts 9. Exclusions Part A does not apply where the instrument has been modified outside a Fenwake workshop, where a fault is caused by a third-party mooring or cable, or where a customer has declined a recommended firmware update in writing. In those cases the service desk will still respond, and work is quoted at the rates in Part B. === [ID:1] similarity=0.3639 (vector 0.7750, term 0.1878) | A01_field_service_policy_and_charges_uk.pdf Fenwake Instruments Ltd Field Service Policy and Charges United Kingdom operations 1.Purpose This document states what a customer holding a support contract with Fenwake Instruments Ltd may expect when an instrument fails in service, what the service desk in Bristol is obliged to do in response, and what is charged for work that falls outside cover. It applies to the Tolvan A3, the Tolvan C5 and the Brannoc telemetry gateway, on every cover level. 2. Scope Part A covers fault handling: acknowledgement, attendance, spares and escalation. Part B sets out the charges that apply outside cover. Neither part describes the goods warranty carried by a new instrument 3.Fault priorities Every ticket is given a priority when it is raised. The priority is set by the effect on the customer's operation, not by which component failed. · Priority 1 - a deployed instrument is not returning data, or is returning data known to be invalid, and no spare is rigged. · Priority 2 - an instrument is degraded but usable, or a spare has been rigged and the primary unit is down. · Priority 3 - a question, a configuration change, or a fault with no operational effect. A priority may be raised by the duty engineer at any point. It is lowered only with the customer's agreement, recorded on the ticket. 4.Acknowledgement during business hours Business hours are 08:00 to 18:00, Monday to Friday, excluding statutory non-working days in England and Wales.Within those hours the service desk is staffed continuously and the targets below are measured from the moment the ticket is raised, by telephone or through the portal, whichever is earlier. An acknowledgement is a named engineer taking ownership of the ticket and telling the customer what happens next. An automatic reply from the ticketing system is not an acknowledgement and does not stop the clock. 4.1 What the target does not cover The acknowledgement target is not a repair target. Attendance and parts are dealt with in section 5, and the two clocks run independently: a ticket may be acknowledged inside target and still take several days to close. 5.Attendance and parts Where a fault cannot be cleared remotely, the service desk arranges attendance.Attendance targets are working-day targets and are quoted from the point at which the customer confirms site access. 5.1Consumables Anti-fouling guards, sacrificial anodes and cable glands are consumables. They are replaced during any attendance and charged at the rates in Part B. === [ID:2] similarity=0.2981 (vector 0.7925, term 0.0862) | A01_field_service_policy_and_charges_uk.pdf
RouteWhenDetail
Service deskBusiness hoursservice@fenwake-instruments.example
Service desk telephoneBusiness hours+441174960188
Out-of-hours pagerAll other times+441174960199
=== [ID:3] similarity=0.2892 (vector 0.7270, term 0.1016) | A09_warranty_statement_service_pack.pdf Fenwake Instruments Ltd Warranty Terms Service pack - warranty terms for the service desk 1. What is covered These are the warranty terms the service desk applies when a customer reports a failure. They apply to every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The warranty covers the instrument, its pressure housing, its connector and any cable supplied with it. It covers failure arising from a defect in materials or workmanship. Where a covered failure occurs, Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both directions. 2. The warranty period Every new Tolvan A3 carries a warranty of 36 months from the date the instrument is delivered. The period runs from delivery rather than from commissioning, and is not extended by a repair carried out under it. 2.1 Instrumentsrepaired underwarranty A repaired instrument carries the unexpired balance of the original period, or ninety days from the return of the repaired instrument, whichever ends later. 3. What is not covered · Fouling, corrosion of sacrificial components, and wear of consumables such as anodes, guards and gland kits. · Damage caused by a mooring failure, a vessel strike, a snagged cable or any other mechanical event outside the instrument. · Damage caused by opening the housing outside a Fenwake workshop, or by breaking a calibration seal. · Drift within the published specification. Drift is a calibration matter, not a defect. · Any instrument whose serial number has been removed or altered. 4. Making a claim A claim is made through the service desk,quoting the serial number and the delivery note.The service desk raises a ticket, arranges return carriage and tells the customer within five working days whether the failure is covered. Where it is not covered, the customer is quoted for the repair before any work starts. 4.1 If the customer disagrees Where a customer disputes a decision that a failure is not covered, the instrument is held unrepaired and the head of service operations reviews the file. The instrument is not returned, scrapped or repaired while a review is open. 5. Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data. loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. 6. Statutory rights === [ID:4] similarity=0.2837 (vector 0.7533, term 0.0824) | A01_field_service_policy_and_charges_uk.pdf
PriorityAcknowledgement targetMeasured from
Priority 130 minutesTicket raised
Priority 24 working hoursTicket raised
Priority 3The next working dayTicket raised
=== [ID:5] similarity=0.2776 (vector 0.7330, term 0.0824) | A04_employee_handbook.docx Employee HandbookFenwake Instruments Ltd - all locations1. Working hereThis handbook sets out the terms that apply to everyone employed by Fenwake Instruments Ltd, whether based at the Bristol workshop, at the Avonmouth calibration laboratory, or working from a customer site or vessel. It forms part of your contract. Where a term is set out in your written statement of particulars and also here, the written statement governs.2. Hours of workStandard hours are 37.5 a week, worked between 08:00 and 18:00, Monday to Friday. Workshop staff work a 07:30 start by agreement with the workshop manager. Anyone rostered to the out-of-hours duty engineer rota is paid a standby allowance for each week on the rota, and an hourly rate for any hour actually worked while on standby.2.1 Time recordingHours are recorded against a job number on the day they are worked. A job number is required for chargeable work, for internal projects and for training. Corrections are made by the line manager rather than by editing a submitted week.3. Annual leaveFull-time employees accrue 26 days of annual leave in each complete leave year, which runs from 1 April to 31 March. Part-time employees accrue pro rata. Leave accrues from the first day of employment and may be taken during the probation period with the line manager's agreement.3.1 Booking leaveAnnual leave is requested in the rota system and confirmed by the line manager. Requests are considered in the order they are received. Service operations will decline a request that would leave the duty engineer rota uncovered, and will say so within five working days so that alternative dates can be chosen.3.2 Carry-overUp to five days of untaken annual leave may be carried into the next leave year, and must be taken by 30 June. Anything beyond five days is carried over only where leave could not be taken because of a business requirement, and only with the written agreement of a director.3.3 Leave on leavingOn termination, accrued and untaken annual leave is paid in the final salary payment. Where more leave has been taken than accrued, the balance is deducted from that payment.4. Sickness absenceReport sickness to your line manager before 09:00 on the first day, by telephone rather than by message. Absence of seven calendar days or fewer is self-certified on return. Longer absence requires a fit note. Company sick pay is paid at normal salary for the first four weeks of a continuous absence and at half salary for the following four weeks, after which statutory sick pay alone applies. CHECKS: passages containing '90 minutes': [0] | containing '30 minutes': [4] | answer contains '90 minutes': True | answer contains '30 minutes' or '4 working hours': False ######## RUN 2: POST /api/v1/chat/completions question='How quickly does Fenwake acknowledge a Priority 1 fault reported outside business hours?' stream=false | HTTP 200 code=0 latency=22.81s ANSWER: Fenwake acknowledges a Priority 1 fault reported outside business hours within 90 minutes of the ticket being raised by a named duty engineer [ID:0]. The target applies on every cover level, and the engineer confirms ownership by telephone and, if requested by the customer, in writing on the ticket [ID:0]. === [ID:0] similarity=0.4826 (vector 0.7948, term 0.3488) | A01_field_service_policy_and_charges_uk.pdf 5.2Access Where a site requires a permit, an induction or a vessel movement, the attendance clock is suspended until access is confirmed in writing. The suspension is recorded on the ticket with the reason. 6.Out-of-hours cover Outside business hours the service desk is not staffed. A duty engineer rota covers every hour of the year, and the out-of-hours number in section 8 pages the engineer on call. 6.1Acknowledgementout ofhours A Priority 1 fault reported outside business hours is acknowledged by a named duty engineer within 90 minutes of the ticket being raised. The engineer confirms ownership by telephone and, where the customer asks for it, in writing on the ticket. The target applies on every cover level; the cover level determines what happens after acknowledgement, not how quickly the call is answered. 6.2Whatfollows acknowledgement Having acknowledged, the duty engineer attempts a remote diagnosis using the telemetry record. Where the fault cannot be cleared remotely, attendance is arranged under section 5 from the start of the following working day, except on Critical cover, where the duty engineer may authorise attendance immediately 6.3Priority 2 and Priority 3 out of hours Priority 2 and Priority 3 tickets raised outside business hours are queued and acknowledged when the service desk opens. The business-hours targets in section 4 then apply from opening. 7.Escalation A customer may escalate at any time, and the service desk escalates on its own initiative when a target is missed. Each step below is a named person, not a queue. · Step 1 - Duty engineer. Owns the ticket and the diagnosis · Step 2 - Service desk lead. Owns the schedule, the parts and the customer communication. · Step 3 - Head of service operations. Owns the commercial consequences and any goodwill offered. · Step 4 - Operations director. Owns the relationship. A step is skipped only where the person is unavailable, and the skip is recorded. Escalation does not restart the acknowledgement clock, which is measured once per ticket. 7.1 Missed targets Where an acknowledgement target is missed, the service desk lead writes to the customer within one working day setting out what happened and what has changed. A missed target is reported in the monthly service review whether or not the customer raises it. 8. Contacts 9. Exclusions Part A does not apply where the instrument has been modified outside a Fenwake workshop, where a fault is caused by a third-party mooring or cable, or where a customer has declined a recommended firmware update in writing. In those cases the service desk will still respond, and work is quoted at the rates in Part B. === [ID:1] similarity=0.3639 (vector 0.7750, term 0.1878) | A01_field_service_policy_and_charges_uk.pdf Fenwake Instruments Ltd Field Service Policy and Charges United Kingdom operations 1.Purpose This document states what a customer holding a support contract with Fenwake Instruments Ltd may expect when an instrument fails in service, what the service desk in Bristol is obliged to do in response, and what is charged for work that falls outside cover. It applies to the Tolvan A3, the Tolvan C5 and the Brannoc telemetry gateway, on every cover level. 2. Scope Part A covers fault handling: acknowledgement, attendance, spares and escalation. Part B sets out the charges that apply outside cover. Neither part describes the goods warranty carried by a new instrument 3.Fault priorities Every ticket is given a priority when it is raised. The priority is set by the effect on the customer's operation, not by which component failed. · Priority 1 - a deployed instrument is not returning data, or is returning data known to be invalid, and no spare is rigged. · Priority 2 - an instrument is degraded but usable, or a spare has been rigged and the primary unit is down. · Priority 3 - a question, a configuration change, or a fault with no operational effect. A priority may be raised by the duty engineer at any point. It is lowered only with the customer's agreement, recorded on the ticket. 4.Acknowledgement during business hours Business hours are 08:00 to 18:00, Monday to Friday, excluding statutory non-working days in England and Wales.Within those hours the service desk is staffed continuously and the targets below are measured from the moment the ticket is raised, by telephone or through the portal, whichever is earlier. An acknowledgement is a named engineer taking ownership of the ticket and telling the customer what happens next. An automatic reply from the ticketing system is not an acknowledgement and does not stop the clock. 4.1 What the target does not cover The acknowledgement target is not a repair target. Attendance and parts are dealt with in section 5, and the two clocks run independently: a ticket may be acknowledged inside target and still take several days to close. 5.Attendance and parts Where a fault cannot be cleared remotely, the service desk arranges attendance.Attendance targets are working-day targets and are quoted from the point at which the customer confirms site access. 5.1Consumables Anti-fouling guards, sacrificial anodes and cable glands are consumables. They are replaced during any attendance and charged at the rates in Part B. === [ID:2] similarity=0.2981 (vector 0.7925, term 0.0862) | A01_field_service_policy_and_charges_uk.pdf
RouteWhenDetail
Service deskBusiness hoursservice@fenwake-instruments.example
Service desk telephoneBusiness hours+441174960188
Out-of-hours pagerAll other times+441174960199
=== [ID:3] similarity=0.2892 (vector 0.7270, term 0.1016) | A09_warranty_statement_service_pack.pdf Fenwake Instruments Ltd Warranty Terms Service pack - warranty terms for the service desk 1. What is covered These are the warranty terms the service desk applies when a customer reports a failure. They apply to every new Tolvan A3 supplied by Fenwake Instruments Ltd, however it was ordered and wherever it is deployed. The warranty covers the instrument, its pressure housing, its connector and any cable supplied with it. It covers failure arising from a defect in materials or workmanship. Where a covered failure occurs, Fenwake repairs or exchanges the instrument at its own option and bears the cost of carriage in both directions. 2. The warranty period Every new Tolvan A3 carries a warranty of 36 months from the date the instrument is delivered. The period runs from delivery rather than from commissioning, and is not extended by a repair carried out under it. 2.1 Instrumentsrepaired underwarranty A repaired instrument carries the unexpired balance of the original period, or ninety days from the return of the repaired instrument, whichever ends later. 3. What is not covered · Fouling, corrosion of sacrificial components, and wear of consumables such as anodes, guards and gland kits. · Damage caused by a mooring failure, a vessel strike, a snagged cable or any other mechanical event outside the instrument. · Damage caused by opening the housing outside a Fenwake workshop, or by breaking a calibration seal. · Drift within the published specification. Drift is a calibration matter, not a defect. · Any instrument whose serial number has been removed or altered. 4. Making a claim A claim is made through the service desk,quoting the serial number and the delivery note.The service desk raises a ticket, arranges return carriage and tells the customer within five working days whether the failure is covered. Where it is not covered, the customer is quoted for the repair before any work starts. 4.1 If the customer disagrees Where a customer disputes a decision that a failure is not covered, the instrument is held unrepaired and the head of service operations reviews the file. The instrument is not returned, scrapped or repaired while a review is open. 5. Limits This warranty is the whole of the remedy for a defective instrument. Fenwake is not liable for loss of data. loss of survey time, vessel standby, or any other consequential loss arising from a failure, whether or not that failure is covered. 6. Statutory rights === [ID:4] similarity=0.2837 (vector 0.7533, term 0.0824) | A01_field_service_policy_and_charges_uk.pdf
PriorityAcknowledgement targetMeasured from
Priority 130 minutesTicket raised
Priority 24 working hoursTicket raised
Priority 3The next working dayTicket raised
=== [ID:5] similarity=0.2776 (vector 0.7330, term 0.0824) | A04_employee_handbook.docx Employee HandbookFenwake Instruments Ltd - all locations1. Working hereThis handbook sets out the terms that apply to everyone employed by Fenwake Instruments Ltd, whether based at the Bristol workshop, at the Avonmouth calibration laboratory, or working from a customer site or vessel. It forms part of your contract. Where a term is set out in your written statement of particulars and also here, the written statement governs.2. Hours of workStandard hours are 37.5 a week, worked between 08:00 and 18:00, Monday to Friday. Workshop staff work a 07:30 start by agreement with the workshop manager. Anyone rostered to the out-of-hours duty engineer rota is paid a standby allowance for each week on the rota, and an hourly rate for any hour actually worked while on standby.2.1 Time recordingHours are recorded against a job number on the day they are worked. A job number is required for chargeable work, for internal projects and for training. Corrections are made by the line manager rather than by editing a submitted week.3. Annual leaveFull-time employees accrue 26 days of annual leave in each complete leave year, which runs from 1 April to 31 March. Part-time employees accrue pro rata. Leave accrues from the first day of employment and may be taken during the probation period with the line manager's agreement.3.1 Booking leaveAnnual leave is requested in the rota system and confirmed by the line manager. Requests are considered in the order they are received. Service operations will decline a request that would leave the duty engineer rota uncovered, and will say so within five working days so that alternative dates can be chosen.3.2 Carry-overUp to five days of untaken annual leave may be carried into the next leave year, and must be taken by 30 June. Anything beyond five days is carried over only where leave could not be taken because of a business requirement, and only with the written agreement of a director.3.3 Leave on leavingOn termination, accrued and untaken annual leave is paid in the final salary payment. Where more leave has been taken than accrued, the balance is deducted from that payment.4. Sickness absenceReport sickness to your line manager before 09:00 on the first day, by telephone rather than by message. Absence of seven calendar days or fewer is self-certified on return. Longer absence requires a fit note. Company sick pay is paid at normal salary for the first four weeks of a continuous absence and at half salary for the following four weeks, after which statutory sick pay alone applies. CHECKS: passages containing '90 minutes': [0] | containing '30 minutes': [4] | answer contains '90 minutes': True | answer contains '30 minutes' or '4 working hours': False